A motor drawing says M470-50A. The supplier quotes 50W470. The mill certificate from another source says 50A470. Are these three different materials?
Usually not. They are the same two pieces of information written in three national formats: the sheet thickness and the maximum core loss the steel is guaranteed not to exceed. Once you know that, a grade name becomes something you can parse, compare and check, and that is a nice small job for Python.
What is inside a non-oriented grade name
For fully processed non-oriented electrical steel (the kind used for motor and generator laminations), the three common naming systems look like this:
| System | Example | Read it as |
|---|---|---|
| GB/T 2521.1 (China) | 50W470 | 0.50 mm, W = non-oriented, loss code 470 |
| IEC 60404-8-4 / EN 10106 | M470-50A | loss code 470, 0.50 mm, A = fully processed |
| JIS C 2552 (Japan) | 50A470 | 0.50 mm, A = non-oriented, loss code 470 |
The loss code is the maximum specific total loss at 1.5 T and 50 Hz (often written P1.5/50 or W15/50), multiplied by 100. So 470 means the steel must not exceed 4.70 W/kg when tested on an Epstein frame under those conditions. The two digits for thickness are hundredths of a millimetre, so 50 means 0.50 mm and 35 means 0.35 mm.
Two things follow from that:
- A lower loss code means a better (lower-loss) grade at the same thickness.
- The number is a ceiling, not a typical value. A real coil of 50W470 normally measures below 4.70 W/kg, and the actual figure is on its mill certificate.
The code
"""Parse non-oriented electrical steel grade names and check a loss budget. Supported naming systems (fully processed, non-oriented): GB/T 2521.1 50W470 -> thickness 0.50 mm, max P1.5/50 = 4.70 W/kg IEC / EN M470-50A -> same information, different order JIS C 2552 50A470 -> same information, different letter The number in the name is the guaranteed MAXIMUM specific total loss at 1.5 T, 50 Hz, multiplied by 100. Typical values on a mill certificate are lower. """ import re from dataclasses import dataclass PATTERNS = [ ("GB", re.compile(r"^(\d{2})W(\d{3,4})$")), # 50W470 ("EN", re.compile(r"^M(\d{3,4})-(\d{2})A$")), # M470-50A ("JIS", re.compile(r"^(\d{2})A(\d{3,4})$")), # 50A470 ] @dataclass(frozen=True) class Grade: name: str system: str thickness_mm: float max_loss_w_per_kg: float # P1.5/50, guaranteed maximum def as_gb(self) -> str: return f"{round(self.thickness_mm * 100):02d}W{round(self.max_loss_w_per_kg * 100)}" def as_en(self) -> str: return f"M{round(self.max_loss_w_per_kg * 100)}-{round(self.thickness_mm * 100):02d}A" def as_jis(self) -> str: return f"{round(self.thickness_mm * 100):02d}A{round(self.max_loss_w_per_kg * 100)}" def parse(name: str) -> Grade: s = name.strip().upper().replace(" ", "") for system, rx in PATTERNS: m = rx.match(s) if not m: continue if system == "EN": loss, thk = m.group(1), m.group(2) else: thk, loss = m.group(1), m.group(2) return Grade(name, system, int(thk) / 100, int(loss) / 100) raise ValueError(f"not a recognised non-oriented grade name: {name!r}") def loss_budget(grade: Grade, core_kg: float) -> float: """Upper bound of core loss in W at 1.5 T / 50 Hz, Epstein conditions.""" return grade.max_loss_w_per_kg * core_kg def check_certificate(grade: Grade, measured_p15_50: float, thickness_mm: float, thk_tol_mm: float) -> list[str]: """Compare mill certificate values with what the grade name promises.""" issues = [] if measured_p15_50 > grade.max_loss_w_per_kg: issues.append(f"P1.5/50 {measured_p15_50} W/kg is above the grade maximum " f"{grade.max_loss_w_per_kg} W/kg") if abs(thickness_mm - grade.thickness_mm) > thk_tol_mm: issues.append(f"thickness {thickness_mm} mm is outside " f"{grade.thickness_mm} +/- {thk_tol_mm} mm") return issues if __name__ == "__main__": for n in ["50W470", "M470-50A", "50a470", "35W300", "M800-50A", "65A800"]: g = parse(n) print(f"{n:>9} -> {g.system:<3} t={g.thickness_mm:.2f} mm " f"P1.5/50 <= {g.max_loss_w_per_kg:.2f} W/kg " f"| GB {g.as_gb():<7} EN {g.as_en():<9} JIS {g.as_jis()}") print() core_kg = 12.0 # example stator + rotor stack mass, take yours from CAD for n in ["50W800", "50W470", "35W300"]: g = parse(n) print(f"{n}: loss budget for a {core_kg:.0f} kg core <= " f"{loss_budget(g, core_kg):.1f} W") print() g = parse("M470-50A") # Example certificate values - replace with the figures on your MTC. # Thickness tolerance: take it from the standard or your purchase order. print(check_certificate(g, measured_p15_50=4.12, thickness_mm=0.498, thk_tol_mm=0.04)) print(check_certificate(g, measured_p15_50=4.85, thickness_mm=0.498, thk_tol_mm=0.04)) Running it
50W470 -> GB t=0.50 mm P1.5/50 <= 4.70 W/kg | GB 50W470 EN M470-50A JIS 50A470 M470-50A -> EN t=0.50 mm P1.5/50 <= 4.70 W/kg | GB 50W470 EN M470-50A JIS 50A470 50a470 -> JIS t=0.50 mm P1.5/50 <= 4.70 W/kg | GB 50W470 EN M470-50A JIS 50A470 35W300 -> GB t=0.35 mm P1.5/50 <= 3.00 W/kg | GB 35W300 EN M300-35A JIS 35A300 M800-50A -> EN t=0.50 mm P1.5/50 <= 8.00 W/kg | GB 50W800 EN M800-50A JIS 50A800 65A800 -> JIS t=0.65 mm P1.5/50 <= 8.00 W/kg | GB 65W800 EN M800-65A JIS 65A800 50W800: loss budget for a 12 kg core <= 96.0 W 50W470: loss budget for a 12 kg core <= 56.4 W 35W300: loss budget for a 12 kg core <= 36.0 W [] ['P1.5/50 4.85 W/kg is above the grade maximum 4.7 W/kg'] Three uses come out of this.
1. Normalising a bill of materials. If drawings, quotes and certificates arrive in different formats, parse() turns them into the same two numbers, so a spreadsheet or a database can compare them. Lower-case input and stray spaces are handled; anything that does not match a pattern raises an error instead of being guessed.
2. A first loss budget. Multiplying the grade maximum by the core mass gives a rough ceiling for iron loss at 1.5 T and 50 Hz. In the example, the same 12 kg core ranges from 96 W with 50W800 down to 36 W with 35W300. That is not the loss your motor will actually see (more on that below), but it is a quick way to compare grades before you ask a supplier for curves.
3. A certificate check. check_certificate() compares the measured P1.5/50 and thickness on a mill test certificate with what the grade promises. The values in the example are placeholders. Use the figures on your own certificate, and take the thickness tolerance from the standard or your purchase order rather than from the script.
Where the simple model stops
- Converting a name is not the same as certifying equivalence. The three standards are closely aligned for these grades, but each has its own grade list, test details and tolerances. A converted name may not exist in the other standard's table. Before you substitute one for another on an order, check the actual standard and the certificate.
- Grade maximum is not motor loss. Real cores run at other flux densities and frequencies, and punching or laser cutting adds loss near the cut edges, especially on narrow teeth. For design work, ask the supplier for loss curves (W/kg vs. T at your frequency) for the specific grade.
- Semi-processed grades (for example EN names ending in
DorE) and AISI M-numbers such as M19 or M27 use different conventions. The script rejects them on purpose. AISI numbers in particular do not encode a loss value you can parse. - Thickness alone does not pick the grade. Thinner sheet lowers eddy current loss, which matters more as frequency rises, but it costs more per tonne and means more laminations per stack.
Picking thickness and grade in practice
For a 50 Hz industrial motor, 0.50 mm grades are the common starting point, and the loss code is where you trade cost against efficiency. For higher-frequency machines such as inverter-driven or high-speed motors, 0.35 mm and thinner grades come into the picture. If you want a fuller overview of the grades, thicknesses and forms (coil, slit strip, cut sheets) that are typically available, this page on non-oriented electrical steel covers them.
Once a grade is chosen, the next question is how much coil a lamination actually consumes. I wrote about that in an earlier post: How Much Coil Does a Motor Lamination Really Use?
If you work with other naming systems, for example in-house mill grades or older national standards, I would be glad to hear how you map them.