Researchers affiliated with ETH Zurich, UC Santa Barbara, and Miguel Hernández University studied one participant temporarily implanted with a 96-electrode visual cortex array. They trained a deep neural network to predict electrically evoked neural activity using pre-stimulation brain activity and stimulation parameters. In this proof of concept, model-selected stimulation more accurately evoked targeted neural activity while using less electrical current. Whether the approach improves safety or generalizes to other patients remains open.