Data centers: 23% of Ireland's power, 29% of a town's water
Data centers now take 23% of Ireland's electricity and 29% of one Oregon town's water. The industry's answer — closed-loop cooling — trades the water problem for a power problem it won't put a number on.
The numbers come from Paris Marx's new book Hyperscale, out today, and a TechCrunch interview with him. His argument is blunt: the buildout is "fundamentally unsustainable" and "completely out of line with a livable planet." What makes it a political story rather than an engineering one is that the backlash is bipartisan — Ron DeSantis and Bernie Sanders are both on record opposing data centers. A data center is physical in a way a chatbot never is: it shows up in your power bill, your water supply, and the noise from the roof.
The local numbers are the story
Marx builds the case from three places, and the figures are all a matter of public record:
Ireland: 23% of a country's electricity. The Central Statistics Office puts data-center consumption at 7,663 GWh in 2025 — 23% of metered electricity, up from 5% in 2015 (1,240 GWh). That's a 6.2x increase in a decade. In 2025 alone, data-center use rose 10% while the rest of the economy grew 2%. Data centers now use more electricity than all urban households combined (18%) and nearly as much as every home in the country put together (28%). Dublin has had a moratorium on new grid connections since 2022 — and consumption kept climbing anyway. A connection freeze controls which projects join the grid; it doesn't control how much power the ones already connected draw.
The Dalles, Oregon: 29% of a town's water. Google's data centers there used 355.1 million gallons of municipal water in 2021 — 29% of the entire town's supply. The use nearly tripled in four years, from 124.2 million gallons in 2017. The number only became public after a 13-month lawsuit: the city sued The Oregonian to keep its own water records secret, and Google paid the city's legal costs. Do the per-person math and it lands harder: 355 million gallons is roughly the annual domestic water use of ~11,900 people (at the USGS figure of ~82 gallons per person per day), in a town of about 16,000. One company's cooling towers drank like three-quarters of the town. (For precision: 355.1M is the city-metered figure; Google's own accounting put its 2021 net consumption lower, at 274.5M gallons. Either number is a quarter-plus of a small city's water.)
Santiago, Chile: communities organizing around water pressure from Google and Microsoft builds — the same pattern, a different aquifer.
The pivot: from renewables to water
Marx's sharpest observation is about the industry's messaging. A year or two ago the pitch was renewables and nuclear. That argument, he says, is largely lost — so the industry pivoted to water, where it can quote national aggregates: agriculture and golf courses use a lot of water too, so why worry about one data center?
Because water isn't a national issue, it's a local one. A national average is the wrong denominator for a town whose aquifer is being drawn down. The fight is always over one grid connection and one water main, and national figures exist to make that fight look small.
The cooling trade-off, in numbers
The industry's technical answer is to move from evaporative cooling — water in, steam out, a constant fresh flow — to closed-loop cooling, where the same water recirculates and chillers re-cool it with electricity. Marx's caveat, in the interview: closed-loop "does require more electricity in order to keep that water cooled down, and that is often not part of what they talk about."
Microsoft's own numbers let me check that. Its December 2024 blog post says the new design, in use since August 2024, consumes zero water for cooling and avoids "more than 125 million liters of water per year per datacenter." Its fleet average water usage effectiveness is 0.30 liters per kWh, down from 0.49 in 2021. So:
| Figure | Value |
|---|---|
| Microsoft's claimed saving, per new site | >125M liters/yr |
| Implied IT energy behind that saving (125M ÷ 0.30 L/kWh) | ~417 GWh/yr, a ~48 MW facility |
| Google's The Dalles water use, 2021 | 355.1M gallons = 1.34B liters |
| One Google campus vs. one Microsoft site's saving | ~10.8x |
The saving is real, but the scale is one site's worth — and the problem is measured in campuses. And the other side of the trade is where the numbers stop: Microsoft describes the extra electricity as a "nominal increase" in annual energy usage. Nominal. An adjective, not a number. No kWh figure is published, and the first zero-water sites only come online in late 2027 — the pilots in Phoenix and Mt. Pleasant start in 2026. Today's fleet still evaporates.
Then there's the part of the loop nobody puts in a press release. Marx again: it's not just water in those pipes — "there's also a lot of coolant in there, a lot of chemicals, and communities where these projects are being located with closed loop cooling systems are becoming increasingly concerned about those coolants leaking out into their water supply." The water you stop evaporating becomes water you store, chemically treated, on site.
The other concession — Microsoft, Amazon, and OpenAI pledging to stop using NDAs in negotiations with local governments — gets the same treatment from Marx: "not a huge difference." Transparency about a project doesn't change what it draws from the grid or the aquifer.
The take
Every fix so far moves the cost to a different meter. Evaporative cooling spends water. Closed-loop cooling spends electricity — in Ireland, where data centers already take 23% of national demand and the grid operator has already said no to new connections — and adds a chemical leak risk nobody has priced. The industry publishes the water number to three significant figures and the energy cost as "nominal."
Until someone publishes the closed-loop energy penalty in kWh per kWh of IT load, "zero water for cooling" is half a balance sheet. And the honest denominator is local: 29% of a town's water, 23% of a country's power. That's the number that shows up in elections — and the one no national average can shrink.
Sources
- TechCrunch, "Why data centers are at the center of the Big Tech backlash" (Paris Marx interview), 2026-11-22: https://techcrunch.com/2026/11/22/why-data-centers-are-at-the-center-of-the-big-tech-backlash/
- Microsoft, "Sustainable by design: Next-generation datacenters consume zero water for cooling", 2024-12-09: https://www.microsoft.com/en-us/microsoft-cloud/blog/2024/12/09/sustainable-by-design-next-generation-datacenters-consume-zero-water-for-cooling/
- Ireland CSO 2025 data-center electricity figures, via The Register, 2026-07-11: https://www.theregister.com/on-prem/2026/07/11/irish-datacenters-now-guzzle-23-of-the-countrys-electricity/5270013
- Data Center Dynamics, "We now know how much water Google's Oregon data centers use", on The Oregonian's records: https://www.datacenterdynamics.com/en/news/we-now-know-how-much-water-googles-oregon-data-centers-use-after-city-drops-lawsuit-against-journalists/
- All arithmetic is my own (Python, 2026-11-22): 125M L ÷ 0.30 L/kWh ≈ 417 GWh/yr ≈ 48 MW average load; 355.1M gal × 3.78541 ≈ 1.34B liters, ~10.8x the 125M L saving; 355.1M gal ÷ (82 gal/person/day × 365) ≈ 11,900 people; Ireland 1,240 → 7,663 GWh = 6.2x, +518%.