AI & ML
ECG-LabWAS: A Laboratory-Wide Association Study Using a Fine-Tuned Single-Lead Electrocardiogram Foundation Model
arXiv eess.SP0 views
arXiv:2611.27221v1 Announce Type: new Abstract: Laboratory testing guides clinical diagnosis but requires blood sampling and processing. The electrocardiogram (ECG) is fast and noninvasive and may carry information about laboratory abnormalities, yet most AI-ECG models target one test at a time using 12-lead recordings. We conducted an exploratory ECG laboratory-wide association study (ECG-LabWAS), fine-tuning an ECG foundation model pretrained on 10.8 million ECGs to screen 50 laboratory tests from single-lead waveforms alone. The model was developed in an emergency-department cohort (MC-MED; 31,826 patients) and applied unchanged to an independent hospital cohort (MIMIC-IV; 115,921 patients). Of 89 abnormality directions (low or high values of each test), 33 met the same screening criteria in both cohorts. Areas under the receiver operating characteristic curve in the two cohorts were 0.841 and 0.838 for elevated NT-proBNP, 0.769 and 0.740 for elevated cardiac troponin, 0.755 and 0.731 for elevated creatinine, and 0.713 and 0.710 for low potassium. Discrimination changed little when the ECG--laboratory matching window was widened from $\pm$1 to $\pm$24 hours. Model predictions reproduced the co-occurrence of observed abnormalities but were about twice as tightly coupled, largely along one shared component consistent with overall illness severity; low potassium, elevated NT-proBNP and troponin, and markers of renal function retained discrimination beyond that of correlated tests. In exploratory analyses, ECG-assisted versions of the modified Glasgow Prognostic Score and the systemic inflammatory response syndrome criteria were associated with in-hospital and one-year mortality. These results identify which laboratory abnormalities warrant analyte-specific study with single-lead ECG.
Source:https://arxiv.org/abs/2611.27221PreviousHybrid-Field Interference Suppression for Low-Complexity Uplink Channel EstimationNextPepDeTech: Anonymous Occupancy Monitoring on a Battery-Powered 2.3k-Zone dToF LiDAR Node with On-Chip Processing and Bluetooth LE Reporting
Related posts
A Practical Workflow for Agent-Driven 3D Asset Generation
0dev.to

Hermes: reminders that carry the check
0dev.to
Bessel-Debiased Pseudo-Marginal MCMC for Generalised Bayesian Inference
0arXiv stat.CO
Revisiting Generalized Median Estimators: Exact Bitwise Computation and Gray Code Acceleration
0arXiv stat.CO
Exact Online $Q_n$ Estimation: Exploiting Sliding-Window Rank Invariance
0arXiv stat.CO
ISC Stormcast For Monday, November 23rd, 2026 https://isc.sans.edu/podcastdetail/10190, (Mon, Nov 23rd)
0SANS ISC