Most residential bathroom remodels fail on paper long before a plumber roughs in a flange. A homeowner tries to squeeze a 60-inch double vanity into a 5x8 alcove, a 30-inch inswing door clips an elongated 28-inch toilet bowl, or a 30x30 shower pan passes minimum building code by a quarter inch while feeling claustrophobic in daily use.
When we built the interactive IRC / NKBA Bathroom Clearance Calculator inside PlanCaliber, a browser-based 2D/3D floor plan and CAD drafting studio, we needed a deterministic pure-TypeScript rules engine (src/lib/cad/bathCalc.ts) with zero runtime dependencies that could:
- Distinguish legal code minimums (IRC P2705.1 / R307.1 / P2708.1) from functional comfort guidelines (NKBA) in a single structured pass.
- Automatically switch fixture geometry across three common US bathroom topologies (
powder_room,single_wall, andprimary_suite). - Catch real physical collisions — opposite-wall shower overlap, wet-wall run overflow, and inswing door-arc strikes — and emit exact inch-delta fix hints.
- Compute net floor tile and 3-wall wet-surround tile takeoffs with 10% waste directly from the resolved geometry.
Here is how the geometry model and rules engine work under the hood.
1. Why Binary Pass/Fail Lies to Remodelers
In US residential space planning, a simple boolean isValid hides the most important decision a homeowner or designer has to make. Under the International Residential Code (IRC), a 30-inch-wide toilet alcove (15 inches from centerline to each adjacent wall or fixture) and 21 inches of clear floor space in front of the bowl meet code minimums (IRC P2705.1 / R307.1). Yet the National Kitchen & Bath Association (NKBA) recommends a 36-inch alcove (18 inches each side) and 30 inches of front clearance.
To surface that exact distinction without false alarms, every individual check returns a three-state enum, and the whole room rolls up to a three-state summary:
export type BathRuleStatus = 'NKBA_PASS' | 'IRC_PASS_TIGHT' | 'FAIL'; export type BathOverallStatus = 'NKBA_COMFORT' | 'IRC_PASS_TIGHT' | 'CODE_FAIL'; export type BathLayoutMode = 'single_wall' | 'primary_suite' | 'powder_room'; Every BathRuleCheck emits both reference thresholds alongside the actual measurement in fractional inches (1/8" precision) and a concrete fixHint telling the user the exact delta needed to pass code or reach NKBA comfort:
const st: BathRuleStatus = toiletSideCenterlineIn < 15 ? 'FAIL' : toiletSideCenterlineIn < 18 ? 'IRC_PASS_TIGHT' : 'NKBA_PASS'; // Example fixHint when FAIL: // "Widen toilet alcove by at least 2\" to reach the 30\" IRC code minimum." That three-tier model lets a remodeler working inside a tight 1950s 5x8 footprint immediately see what is a hard code violation (CODE_FAIL) versus what legally passes code while sitting inside the tight band (IRC_PASS_TIGHT).
2. Three-Topology Geometry Classifier (powder_room vs single_wall vs primary_suite)
A bathroom clearance engine cannot treat all rooms as one wall. The same 28-inch elongated toilet projection behaves completely differently depending on whether the room is a narrow 3x6 powder room, a classic 5x8 single-wet-wall hall bath, or an 8x10 two-wall primary suite.
We classify the layout deterministically from the fixture selection and room width:
const layoutMode: BathLayoutMode = input.fixtureType === 'none' ? 'powder_room' : input.roomWidthIn >= 84 ? 'primary_suite' : 'single_wall'; Each topology drives different clearance equations:
A. Single-Wet-Wall Standard Bath (5x8, 5x9, room width < 84")
All plumbing runs along one continuous wall to minimize stack and venting cost: tub or shower at the left end (wetEndDepth), followed by the toilet alcove (toiletAlcoveWidthIn), followed by the vanity (vanityWidthIn).
const autoToiletFront = input.roomWidthIn - input.toiletProjectionIn; vanityFrontClearIn = input.roomWidthIn - input.vanityDepthIn; wetWallUsedIn = wetEndDepth + input.toiletAlcoveWidthIn + input.vanityWidthIn; const lengthOverflow = Math.max(0, wetWallUsedIn - input.roomLengthIn); const widthOverflow = Math.max(0, wetSpanWidth - input.roomWidthIn); wetWallOverflowIn = Math.max(lengthOverflow, widthOverflow); Notice how 5x8 (60" x 96") lands right on the razor's edge: a 30" alcove tub + 30" toilet alcove + 36" vanity sums to exactly 96" (0" overflow). Upgrading to a 32" tub or a 42" vanity without lengthening the room immediately triggers a wall_run_fit failure with the exact overflow in inches.
B. Two-Wall Primary Suite (roomWidthIn >= 84")
At 7 feet wide or more, fixtures split across opposite walls: vanity + toilet along the top wall, shower/tub + entry door along the bottom wall. Here, the naive formula roomWidthIn - toiletProjectionIn would be dangerously wrong whenever a wide walk-in shower extends far enough horizontally to sit directly across from the toilet bowl.
We test horizontal overlap explicitly before computing front clearances:
const vanityEndX = input.vanityWidthIn; const toiletStartX = vanityEndX; const showerOverlapsVanity = wetLen > 0; const showerOverlapsToilet = wetLen > toiletStartX + 2; const autoToiletFront = input.roomWidthIn - input.toiletProjectionIn - (showerOverlapsToilet ? wetDepth : 0); vanityFrontClearIn = input.roomWidthIn - input.vanityDepthIn - (showerOverlapsVanity ? wetDepth : 0); That 2" tolerance avoids false positives when a glass shower panel terminates right at the vanity-to-toilet boundary, while immediately subtracting wetDepth if a 60" or 72" shower overlaps into the toilet's front legroom zone.
C. Galley Powder Room (fixtureType === 'none')
With no tub or shower, the toilet mounts on the left end wall facing a shallow (18" or 21") vanity on the right end wall, leaving a shared middle zone:
const clearMiddle = input.roomLengthIn - input.toiletProjectionIn - input.vanityDepthIn; toiletFrontClearIn = input.toiletFrontClearOverrideIn ?? clearMiddle; vanityFrontClearIn = clearMiddle; In a classic 36" x 72" (3x6) powder room with a 28" toilet and 18" shallow vanity, clearMiddle is 72 - 28 - 18 = 26" — legally passing the 21" IRC minimum (IRC_PASS_TIGHT), whereas swapping in a 21" standard vanity plus a 30" toilet collapses clearMiddle to 21" right at the code cliff.
3. Double-Vanity Center-to-Center Math (vanityWidthIn - 30)
Double vanities are one of the most frequent IRC failures in remodels. IRC P2705.1 requires:
- At least
15"from each sink's centerline to the nearest side wall, AND - At least
30"center-to-center between adjacent lavatories (NKBA recommends36"center-to-center).
When a cabinet has two bowls pinned at the 15" minimum edge inset on both ends, the maximum center-to-center spacing available between the two drains is simply:
const doubleSinkCenterToCenterIn = input.sinkCount === 2 ? input.vanityWidthIn - 30 : null; That one-line invariant immediately explains why a 48" or 54" double-sink vanity cannot meet IRC (48 - 30 = 18" OC < 30"), why 60" is the exact IRC minimum (60 - 30 = 30" OC -> IRC_PASS_TIGHT), and why 66"+ is needed to hit NKBA's 36" elbow-room guideline (NKBA_PASS).
4. Catching Inswing Door-Arc Collisions Without Heavy Polygon Clipping
Door collisions ruin real floor plans, especially when an existing 30" or 32" interior door swings inward into a 60"-wide hall bath. Rather than running a general-purpose polygon intersection library for orthogonal bathroom layouts, we evaluate the exact horizontal X-span overlap and perpendicular swing clearance per topology:
// Single-wall bath: door sits on bottom right wall opposite the vanity/toilet run const doorX = Math.max(wetEndDepth + 2, input.roomLengthIn - input.doorWidthIn - 3); const doorOverlapsToiletX = doorX < toiletEndX - 1; const doorHitsToilet = input.doorType === 'inswing' && doorOverlapsToiletX && input.doorWidthIn > autoToiletFront; const swingFail = input.doorType === 'inswing' && (input.doorWidthIn > doorSwingAvailableIn || doorHitsToilet); const swingTight = input.doorType === 'inswing' && !swingFail && doorSwingAvailableIn - input.doorWidthIn < 4; Look at what happens on our standard 5x8 preset (60" wide, 28" toilet projection, 21" vanity):
- Clear floor in front of the vanity is
60 - 21 = 39". - Clear floor in front of the toilet is
60 - 28 = 32". - A
30"inswing door clears the toilet by only2"if it overlaps horizontally — or collides outright if someone swaps in a32"accessible door (32 > 32/< 4"tight margin). - Switching
doorTypeto'pocket'or'outswing'zeroes out the inswing encroachment immediately, letting the user test trade-offs in real time on the live 2D SVG plan.
5. Deterministic Tile & Wet-Surround Takeoffs
Once the fixture boxes resolve, computing preliminary floor tile and tub/shower surround tile quantities takes eight lines of arithmetic — subtracting the tub/shower and vanity footprints from gross room area, adding 10% standard cut/breakage waste, and sizing a 3-wall wet surround to 72 inches (6'-0") above the pan:
const grossFloorSqFt = round1((input.roomWidthIn * input.roomLengthIn) / 144); const wetFixtureSqFt = wetDims ? round1((wetDims.w * wetDims.d) / 144) : 0; const vanitySqFt = round1((input.vanityWidthIn * input.vanityDepthIn) / 144); const netTileFloorSqFt = round1(Math.max(0, grossFloorSqFt - wetFixtureSqFt - vanitySqFt)); const tileOrderWith10PctWasteSqFt = Math.ceil(netTileFloorSqFt * 1.1); // Preliminary 3-wall tub/shower surround tile estimate (72" height) const wetWallSurroundSqFt = wetDims ? Math.ceil((((wetDims.w + wetDims.d * 2) * 72) / 144) * 1.1) : 0; Because the entire module is pure TypeScript with clamped finite inputs (clamp(v, min, max)), every slider drag or numeric edit updates all 7 code checks, the dimensioned 2D plan preview, and the tile quantities in under a millisecond on the client — and our Node test suite verifies every single IRC/NKBA boundary (15", 18", 21", 30", 36", 900 sq in, door collisions, and overflow) directly without a browser.
Try the Live Calculator & 2D/3D Bathroom Studio
You can test your own room dimensions, switch between 5x8, 5x9, 8x10, and 3x6 presets, and push the verified footprint straight into our 2D/3D CAD editor:
- Free IRC / NKBA Bathroom Clearance Calculator: plancaliber.com/calculators/bathroom-clearance-calculator
- Kitchen & Bath Remodel CAD Studio: plancaliber.com/kitchen-bath-plans
- Live Browser 2D/3D Floor Plan Editor: plancaliber.com
Drafting, live 3D cutaway views, and clearance checks are free in the browser with no account required. When you want unwatermarked 1/4"=1'-0" vector PDFs (A-101 + M-101), 2400px PNG, and SVG, the one-time Clean Print & Share Pass is $9 (or $19 once for the full 5-sheet CAD package including layered AutoCAD R12 .DXF, 3D .OBJ, and framing/drywall .CSV), backed by a 14-day instant refund policy. (PlanCaliber produces preliminary space-planning drawings — always field-verify dimensions and confirm local building department requirements with your AHJ or licensed professional before construction.)