Backend
Mechanistic Analysis of Unified Proximity-Tactile Observation by a Capacitive Fingertip Array Constrained by a Metal Phalanx
arXiv cs.RO0 views
arXiv:2611.26950v1 Announce Type: new Abstract: A capacitive fingertip array on a metal phalanx under thin silicone skin senses centimetre-scale conductive targets by fringing fields and contact force by dielectric compression. Electrode-to-body parasitics exceed the useful proximity increment by one to three orders of magnitude, and crosstalk and time-division-multiplexing (TDM) settling prevent identifying the capacitance-to-digital converter (CDC) reading with the electrode-target capacitance. The array is modelled as a multi-conductor system (sensing electrodes, driven-shield nodes, phalanx ground and an external target). The CDC measurand follows from the Maxwell capacitance matrix, with each inactive termination in the observation operator. Three mechanisms are examined: driven-shield hiding of shield-branch current and gain/phase-mismatch leakage; distinct far- and near-field operators; and TDM settling as a frame-rate limit set by shield load. A single layer used for both proximity and force reads Delta C = Delta C_force + Delta C_dielectric(epsilon_target), so its force map cannot be material-independent. A dual-array stack is analysed: the outer array is grounded as a Faraday screen during contact, and the inner array reads silicone-gap compression. FEM simulations give a monotonic, nonlinear contact response (4.6 fF at 0.05 mm to 370 fF at 0.5 mm on a 1.08 pF base), a nylon-versus-metal difference of at most 0.3 fF at exported-matrix resolution (not mesh-converged), mutual-term cancellation under driven-shield readout, and about 1 fF crosstalk on the coarse mesh. In proximity mode, electrode-shield coupling of 1.47 pF makes 10^{-3}-10^{-4} mismatch a quantitative gate: a 15.9 fF increment at 5 mm equals the leakage at |epsilon_A| ~ 10^{-2}. Force map, mechanical crosstalk and all bench quantities remain unvalidated; the equations and FEM evidence are a baseline for prototype calibration, not measured performance claims.
Source:https://arxiv.org/abs/2611.26950PreviousRoboCap-10k: A Metrically Accurate Egocentric Dataset for Robot LearningNextRoboDyna: A Benchmark for Evaluating Robotic Manipulation under Physically Grounded Dynamics
Related posts
GrapheneOS Accuses Google of Kneecapping Its Android Partners Using Pixel Exclusives
0Slashdot
Show HN: Open-source MCP server to check AI search crawler readiness
0Hacker News Show
Show HN: AI code review in VS Code with your own API key or Ollama, no account
0Hacker News Show
Using clearscreen in Linux and Android (under Termux)
0Rust Users Forum
Concret Opaque Type
0Rust Users Forum
Private AI code review in VS Code with a local Ollama model
0dev.to