AI & ML
Physics-Aware Zero-Shot Learning for Low-Dose CT from a Single Sinogram
arXiv eess.IV0 views
arXiv:2504.07927v2 Announce Type: replace Abstract: Low-dose computed tomography (CT) imaging remains a persistent challenge, especially under heterogeneous acquisition conditions. Zero-shot learning, which enables models to learn directly from individual images without external supervision, represents a compelling approach to mitigate distribution mismatches arising from variations in scanner hardware, imaging protocols, and patient demographics. However, most existing zero-shot approaches employ down-sampling operations that reduce spatial resolution and cause domain shifts, which become particularly evident when applied to raw sinogram data. Here, we propose a physics-aware zero-shot CT denoising framework to exploit the conjugate symmetry property intrinsic to CT sinograms. Conjugate X-ray pencil beams traverse identical anatomical paths and ideally yield the same expected attenuation values but with independent noise realizations. By randomly mapping sinogram values between conjugate-ray pairs, we synthesize structurally consistent yet noise-diverse sinogram pairs, enabling self-supervised network training without external data. The resulting lightweight denoising network demonstrates strong generalization across low-dose simulation, clinical helical CT, and preclinical photon-counting CT datasets. Quantitative and qualitative results demonstrate competitive denoising performance, with favorable noise suppression and structural preservation across diverse acquisition settings. This work establishes a generalizable and data-efficient paradigm for CT denoising that integrates physical redundancy into learning-based image reconstruction. The code for the proposed method is openly available at: https://github.com/shiyongyi/Physics-Aware-Zero-Shot-CT-Sinogram-Denoising
Source:https://arxiv.org/abs/2504.07927PreviousIncorporating synthetic data from diffusion models supports echocardiography downstream tasksNextQUTCC: Quantile Uncertainty Training and Conformal Calibration for Imaging Inverse Problems
Related posts

Nvidia isn’t selling any more AI chips to China
0The Verge
Nvidia clarifies when it will — and won’t —keep financing neoclouds
0TechCrunch

Google Home speakers get a major Gemini upgrade ‘soon,’ but only for paid subscribers
09to5Google

NVIDIA's CEO Shake-Up Exposes a Costly Prediction Market Deadline
0HackerNoon
Lumi-4B AI Model: Everything You Need to Know
0HackerNoon
The End of the Mouse: How AI Could Change the Way We Use Computers
0HackerNoon