Mouve's production runs on six small virtual machines in Helsinki. Everything else runs in our office in Tallinn, on seven secondhand machines: two HP Z440 workstations, a dual-Xeon workstation board with three GPUs, a Dell PowerEdge T40 tower, a Dell Latitude laptop with the lid closed, and two small desktop PCs.

The office end of Mouve: the two HP Z440s on the bottom shelf, the Dell T40 and a UPS above them, the rackmount cases higher up, and the small PCs in the mesh cabinet on the right.
Together they are 160 threads, 369 GB of RAM and about 10 TB of disk. They run our CI, the dev environment, the agents that write much of our code, the monitoring, the backups and the GPU work. This post is about the hardware: why I chose it, how I reach it when it hangs, and the things that broke. It follows two posts about our costs, what our CI would cost on hosted runners and what our CI fixes measured, which say the hardware is cheap to run. That is true, and it leaves out how much work goes into making it dependable. I leave out purchase prices here; the comparison I care about is running cost.
Why secondhand workstations
The lease includes electricity. I confirmed that on 2026-09-04, and it changes the usual homelab advice. The standard argument against a dual-socket Xeon is that it burns its purchase price in power. Here a 150 W box costs us the same to run as a 15 W one.
So I judge hardware on capacity, heat and noise. The filter for the workstations was a platform with registered ECC memory that is easy to find used (LGA2011-3 sockets, the C610 family of chipsets). A rack server with small fast fans is out because people sit in the office.
That is a real advantage, and it has limits. Over the last 30 days the whole cluster averaged 27 cores and 169 GB, and the hourly 95th percentile was 105 cores. The machines are sized for the peaks, which come from CI and agents. On the evening of 2026-11-20, kubectl top nodes showed about 13.6 cores and 127 GiB in use across all seven. Idle capacity costs us nothing, and I won't pretend it is a feature.
What each box does
| Machine | Threads / RAM | Role |
|---|---|---|
| Two small PCs and a Dell T40 | 4 each, 10 to 16 GB | The three control-plane nodes, which hold etcd. |
| HP Z440 (first) | 44 / 128 GB | CI runners, image builds, the registry mirror, the UPS reader. One 2 TB data-centre NVMe. |
| HP Z440 (second) | 44 / 128 GB | Dev environment, more CI, an RTX 3060 for model work. Still runs Ubuntu. |
| Dual-Xeon ASUS workstation board | 48 / 64 GB | Three RTX A2000 GPUs, the S3 store for backups, the agent workers. Still runs Ubuntu. |
| Dell Latitude 5501 | 12 / 16 GB | Overflow for light CI jobs. Joined on 2026-10-24. |
The three control planes are deliberately boring. I learned why on 2026-05-20.
The consumer SSD that taught us about etcd
Before the current cluster, one control-plane node had a consumer 2.5-inch SATA SSD. SMART said it was healthy. It still made the node flip between Ready and NotReady about 16 times in 100 minutes.
The cause was fsync. etcd writes its log and waits for the disk to confirm it. A consumer drive without power-loss protection confirms slowly, and ours took 200 to 500 ms per write when it should take under 10. containerd then blocked on the same disk, the kubelet's calls to it timed out, and the node was marked down. From outside it looked like a network flap.
The rule I took from it is simple: etcd and anything that syncs goes on a drive with power-loss protection. The control planes now boot from Intel data-centre SATA SSDs. One also has a consumer NVMe that arrived with the box. I gave it one job, staged etcd snapshots, because a torn snapshot can be detected and retaken and a torn etcd log cannot.
The consumer SSD that did not need to be fast, and was not
The same lesson came back in a different place. On 2026-08-30 I measured one Z440 that felt slow in ways that looked like four different problems. CI containers stuck for minutes unpacking, the kubelet's health check stalled, kubectl exec hung, and storage replicas faulted.
All of it traced to one cheap SATA SSD with no DRAM cache that held the OS partition, container layers and every emptyDir. It was 92 to 99% busy at 13 MB/s of writes while the 2 TB NVMe next to it sat at 13%. I moved /var to the NVMe in September, and the 95th-percentile write latency on that path went from 193 ms to 17 ms.
Then on 2026-11-16 I gave the other Z440 a 250 GB consumer SATA SSD (a used drive with 30,548 power-on hours) as its CI cache. On a busy night the runners wrote the whole drive in about 20 to 25 minutes and deleted about as much. Write throughput fell from over 200 MB/s to about 55 MB/s, with latency up from 4 ms to 15 to 25 ms.
The weekly TRIM had run, and latency was best right after it, then tripled within the hour. My guess is that without regular TRIM the drive had almost no clean blocks to work with. It fits the data, but I haven't proved it. I now trim every 15 minutes with a small CronJob, and I took that node out of the CI pools until it has a share it can drain.
The inode table that filled while the disk was 80% free
Bytes were not the only thing that ran out on those CI cache disks. Inodes did too, and they did it first.
On 2026-10-23 every job on the self-hosted pools started failing with No space left on device, while df -h showed 78 to 87% used. df -i showed 99%. Each CI working tree is only about 300 MB, but it is 20,000 to 30,000 inodes. Dozens of agent pull requests produced 25 to 95 finished runner pods a minute, and the reclaimer that deletes old trees managed 12 to 20 per minute. The inode count went from 0.5% to 99.9% used in two hours.
Nothing paged, because our alerts read bytes only and the stock inode alert waits two hours.
On 2026-11-16 the same thing happened faster on the smaller SSD. It has about 15 million inodes against 39 million on the NVMe, and it went from 73% free to 80,000 inodes free in an hour. I made the reclaimer speed up as the disk fills, shortened the alert windows, and recorded the fix for the real cause: format the disk with more inodes. Measured on that night, our cache used 13 to 14 KB per inode, so ext4's default of one inode per 16 KiB runs out first.
The class of failure is that a small cache outruns settings that were tuned for a big one. The rule I wrote down: the inflow a node is given must stay below the rate its cache disk can drain.
A machine check, and nobody went to the office
At 19:24 UTC on 2026-10-02 the second Z440 stopped. Not a reboot: a freeze. The switch port stayed up at gigabit but received nothing, so neither the host nor its management engine was sending. The cluster marked it NotReady, and it stayed down until 23:00.
The cause, read off the BIOS screen after the recovery boot, was a fatal machine check: an uncorrectable memory read error on the first CPU's memory controller, DIMM 1 or 2. The error came two minutes into a burst of heavy CPU work that took the processor package from 61 to 80 °C, on a board with no memory fan fitted. The BIOS prints "Memory configuration requires a Memory fan and this fan is not detected" on every boot, and halts until someone presses Enter.
On 2026-10-25 a full 32 GB memtester pass came back clean, with no corrected or uncorrected errors on any of the four DIMMs after 4 hours 40 minutes at about 40 °C. I put the original error down to heat, because the case fans were not running at the time, and I did not replace the DIMM. I haven't proved that, and I alert on memory errors now.
The more useful lesson was the 3.5 hours. Postgres had a healthy second replica on the other Z440, but every dev workload carried a hostname pin from an earlier move, so nothing could start anywhere else. I replaced the pins with a role label and added a CI guard that fails on any single-node pin. A failover drill the next morning moved dev's database to the other node with about 45 seconds of downtime. The API image still took 9 minutes 11 seconds to pull there, because that node had never run that tag.
Reaching a frozen machine without a keyboard
Both Z440s have Intel AMT, the management engine that sits below the operating system. It gives us remote power control with the machine fully off, and a serial console over the network. I use plain HTTP calls to it, no vendor tools. The first Z440's AMT was dark when we last checked on 2026-10-03, and we have not verified it since.
The traps, in the order I hit them:
- AMT takes its own DHCP lease with the same MAC address as the host, so scanning the host's address for the AMT port shows it closed while it is alive somewhere else.
- The management engine's network stack only starts after a full cold power-off. Warm reboots leave a freshly activated AMT dark. Talos reboots by kexec by default, which skips the firmware entirely, so you must ask for a power cycle when firmware matters.
- On 2026-10-02 the AMT was dark together with the frozen host. Bouncing the router port brought it back within about 20 seconds. That works only for the machine that has a port of its own, which I now know.
- I had written that BIOS text never travels over the serial console. It does, if you set a one-shot boot option before the reset. That let us answer the machine-check and fan screens remotely.
Neither Z440 has a memory fan fitted, so every cold boot still needs someone, or an agent on the serial line, to press Enter. I have a part number for a shroud with a fan. I have not fitted one.
The network loop that broke etcd
For about six weeks the office control plane had two etcd members and no fault tolerance. One of the three machines, a small PC, had died on 2026-09-01 without a cause I could find, and no POST output reached us remotely. On 2026-10-12 I moved its boot SSD into the Dell T40, and the node came back with its identity, rejoined as the same etcd member and caught up from a snapshot.
Before that, on 2026-10-01, the control plane started losing its leader about 39 times an hour. The API server's 99th-percentile latency went from 0.046 s to 2 to 7 s. Watches got HTTP 429s. The controller manager restarted 63 times a day per control plane, and CI runner controllers crash-looped, so CI queued.
I suspected the disks first, because of the earlier incident. They were fine: Intel data-centre SSDs, 0.18 ms average write, no slow step in any trace.
The cause was the network. Our nodes talk over a mesh VPN, and our CNI, Cilium, carries its VXLAN overlay on top of that mesh. The VPN daemon advertises every local address as a possible endpoint, including the CNI's own. It sent some of its own encrypted packets into the overlay, which wrapped them and sent them back into the VPN. The loop overflowed the tunnel interface's queue and dropped 1,000 to 13,000 packets a second in bursts. The etcd peer link uses the same interface. With two voters the leader needs the other to answer within one second, and each burst missed that.
The fix was four routing rules on every node that make the VPN daemon's own packets unreachable for the pod and service ranges. A DaemonSet asserts them every 30 seconds, so a reboot cannot lose them. After they went in at 09:14 UTC on 2026-10-03: zero elections, zero drops. I never found what started it on 2026-10-01. The rules make the trigger irrelevant.
The existing alert described the symptom, slow etcd requests, and said nothing about why. I added alerts for tunnel packet drops, watch-cache re-initialisation and control-plane restarts, each backtested against the history.
Moving to Talos
I started Kubernetes on k3s in March 2026. At the end of May I planned the move to Talos: reinstall the same physical hardware, one node at a time.
Talos has no shell and everything goes through an API. The price is that tasks you would do over ssh become small pods, such as the guard pod we use to check routing rules. Today five of the seven nodes run Talos. The two GPU machines still run Ubuntu. The one with the RTX 3060 stays on Ubuntu because iterating on NVIDIA drivers is faster on a stock OS than through Talos system extensions, where every driver bump means rebuilding the image and reflashing the node.
The best thing it bought us was the 2026-10-12 hardware swap above: the node's identity lived on its boot disk, so a different machine came up as the same etcd member.
Storage choices
I ended up with three kinds of storage, and the rule is what the data needs when it is lost.
- Longhorn for volumes that must survive a node, such as dev Postgres, Prometheus and the identity provider's database. It is on enterprise or at least decent disks, with two replicas where the disks allow. I evicted it from the busiest CI node on 2026-09-12 and left that node's 2 TB NVMe to CI and the OS. Longhorn runs with disks only on nodes we label for it, so a new node holds no replicas by default.
- Local disks for caches. A CI cache can be lost, so it gets whatever is fastest and is deleted constantly.
- An S3-compatible store on two mirrored spinning disks for backups and archives. It replaced Cloudflare R2 for everything except production photos on 2026-09-29, after R2 cost $11.66 in September.
That last choice has a cost I accepted knowingly. The backups and the things they protect now share a building. A fire, a theft, or a bad write that the mirror copies would take both. The cheap fix is a copy on another site, and I have not done it.
What I would buy differently
- Enterprise drives for anything that syncs or churns. Every disk problem above was a consumer drive being asked to do a data-centre job. A data-centre SATA SSD is the cheapest fix we have found.
- Three control planes from the first week. I ran with two for six weeks and had no margin when the network failed.
- A memory fan on both Z440s. It removes the one remaining manual step on every cold boot, and it may remove the heat I blame for the machine check.
- Corrected-error counters from day one. The kernel saw a storm of corrected errors on the memory controller before the fatal one, and nothing in my monitoring did.
- UPS monitoring on every UPS. On 2026-10-29 one went into continuous-tone overload carrying two workstations and nothing alerted, because the monitor for the other had lost its connection. The dual-Xeon box has no UPS today.
- Inodes sized at format time. Cheap to do then, a full reformat later.
None of this is glamorous. All of Mouve's infrastructure costs about EUR 85 a month to run, of which about EUR 74 is the Hetzner VMs for production, and the office electricity is in the rent. What the office cluster costs me is attention: the nights when a freeze, a full table or a loop teaches me something a hosted service would have hidden.