Waveguide to coax transitions: where the loss actually goes
Every millimetre-wave bench has a few of these: a rectangular waveguide flange on one side, a 2.92 mm or 1.85 mm connector on the other, and a spec sheet claiming 0.3 dB insertion loss.
In practice you measure 0.6 dB and spend an afternoon blaming the cable. Here is where the loss actually comes from, and what to check before you send the part back.
The transition is a mode converter, not a connector
A rectangular waveguide carries TE10. A coaxial line carries TEM. The transition has to convert one into the other, and it does so over a physical length — typically a quarter to a half wavelength in guide.
That means:
- Bandwidth is a design choice. A transition optimised for WR28 full band (26.5–40 GHz) will have a different loss profile than one optimised for a narrow sub-band. If a vendor quotes one number, ask at which frequency.
- The probe depth matters. The coax centre conductor penetrates the broad wall of the guide by a fraction of a wavelength. Tolerance on that depth directly moves the return loss.
- There is always a step in impedance. Even a good design has a small reflection at the junction; that is what the return loss spec is telling you.
Where 0.6 dB comes from
Split the measurement:
| Contribution | Typical at 30 GHz |
|---|---|
| Waveguide loss, 20 mm of WR28 | 0.05 dB |
| Transition itself | 0.25 dB |
| Flange interface misalignment | 0.10–0.30 dB |
| Connector mating and cable | 0.10 dB |
The flange line is the one that surprises people. Two UG-599 flanges bolted together with a slight lateral offset — a few tenths of a millimetre — produce a reflection that looks like extra loss in a swept measurement but is actually mismatch. It disappears if you measure with a proper cal kit and look at S11 instead of S21.
Practical check: if S21 shows ripple with period consistent with the guide length, you have a mismatch problem, not an absorption problem. Loss from absorption is smooth. Loss from mismatch ripples.
Alignment pins are not optional
At 40 GHz the wavelength in WR28 is about 5 mm. A 0.2 mm offset is 4 percent of a wavelength — enough to cost you a couple of tenths of a dB and to make repeatability terrible.
Use flanges with alignment pins and matching holes, not just bolt circles. And torque in a cross pattern, not around the circle, so the flange faces stay parallel.
What to ask a supplier
- Insertion loss at the band edges, not just mid-band
- Return loss, both ports, across the full band
- Whether the connector is field-replaceable — a damaged 1.85 mm interface on a fixed transition means scrapping the whole part
- Flange type and whether alignment pins are included
We build waveguide to coaxial adapters at DB Design covering WR28 through WR340, with 2.92 mm, 2.4 mm and 1.85 mm connectors. The loss breakdown above is from our own bench measurements on 20 mm WR28 transitions.